Affordable, Reliable, Flexible, Simple!
Our Machines Make Your Designed PET Bottles Easy!
During normal production, it is necessary to use chiller to cool down the preform mold, injection machine, and stretch blow molding machine and blowing mold to make sure the injection machine and stretch blow molding machine are in full capacity operation. Water cooled chiller is efficient in terms of cost. However air cooled chiller is more flexible to any working circumstances. The picture shown below is a water cooled chiller. Cooling fan is placed on the top part of the unit for the air cooled chiller.
Model SIC- |
3W 3A |
4W 4A |
5W 5A |
8W 8A |
10W 10A |
12.5W 12.5A |
15W 15A |
20W 20A |
25W 25A |
|
Capacity |
KW |
8.54 |
11.9 |
15 |
21.2 |
28.4 |
34.9 |
43.1 |
56.8 |
69.8 |
Power |
KW |
2.75 |
3.8 |
4.66 |
7.02 |
9.79 |
12.54 |
14.25 |
20.22 |
25.08 |
Compressor |
type |
scroll |
Semi-hermetic |
|||||||
Power KW |
2.2 |
3 |
3.7 |
5.5 |
7.5 |
10 |
11 |
7.5x2 |
10x2 |
|
Refrigerant |
R22 |
|||||||||
Thermostatic Expansion Valve |
||||||||||
Evaporator |
Tube-in shell |
|||||||||
Condenser |
Water cool tube-in-shell type |
|||||||||
Air cool Fan KW |
Tube-fin |
|||||||||
0.3 |
0.3 |
0.4 |
0.3x2 |
0.4x2 |
0.6x2 |
0.6x2 |
0.65x2 |
0.65x2 |
||
Pump |
Power KW |
0.55 |
0.75 |
1.5 |
2.2 |
|||||
Flow L/min |
110 |
130 |
200 |
310 |
||||||
Dimension CM |
Water cool |
100x60x85 |
157x60x85 |
157x85x100 |
180x120x120 |
|||||
Air cool |
100x80x90 |
120x85x95 |
140x95x120 |
140x100x140 |